5.4. ORIGAMI: A Code for Computing Assembly Isotopics with ORIGEN
ORIGAMI computes detailed isotopic compositions for light water reactor assemblies containing UO2 fuel by using the ORIGEN transmutation code with pre-generated ORIGEN libraries, for a specified assembly power distribution. The fuel may be modeled using either lumped or pinwise representations with the option of including axial zones. In either case, ORIGAMI performs ORIGEN burnup calculations for each of the specified power regions to obtain the spatial distribution of isotopes in the burned fuel. Multiple cycles with varying burn-times and downtimes may be used. ORIGAMI produces several types of output files, including one containing stacked ORIGEN binary output data (“ft71 file”) for each depletion zone; files with nuclide concentrations at the last time-step for each axial depletion region, in the format of SCALE standard composition input data or as MCNP material cards; a file containing the axial decay heat at the final time-step; and gamma and neutron radiation source spectra.
5.4.1. Acknowledgments
ORIGAMI is based on the PinDeplete code developed by Steve Skutnik and also includes techniques taken from the Orella code written by Ian Gauld (retired). Support for development of ORIGAMI was provided by the U.S. Department of Energy, Office of Nuclear Energy, Nuclear Fuels Storage and Transportation Planning Project.
5.4.2. Introduction
ORIGAMI (ORIGEN Assembly Isotopics) provides the capability to perform isotopic depletion and decay calculations for a light water reactor fuel assembly model using one or more ORIGEN calculations. The assembly may be modeled using either lumped or pinwise representations with the option of including axial zones. ORIGAMI automates the performance of ORIGEN depletion calculations for each region and thus simulates zero-, one-, two-, and three -dimensional (0D, 1D, 2D, and 3D) modeling of a fuel assembly. Multiple cycles with different specific powers and exposure and decay times may be treated, and the power distribution is described in terms of fractional pin powers in the XY plane and axial distributions along the Z axis, which define the burnup regions for the ORIGEN computations. ORIGAMI allows for easy and flexible material composition specification through the standard SCALE mixture processor for composition input, the same as in TRITON (see XSPROC chapter). While ORIGAMI cannot presently treat axially non-uniform lattice features (e.g. axially varying enrichment or the partial-length rods found in many boiling water reactor designs) within a single input, these problems can still be easily modeled by splitting the problem across sequential ORIGAMI input cases residing on the same file.
The ORIGEN calculations performed by ORIGAMI use the methodology originally established for the SCALE sequence ORIGEN-ARP (see the ARP section). This approach provides an efficient mechanism to perform stand-alone reactor depletion calculations using pre-generated ORIGEN libraries which contain self-shielded, collapsed one-group cross sections as a function of selected independent variables, such as burnup, enrichment, and moderator density, for different reactor systems. Typically the data in these libraries are obtained from 2D, multigroup lattice transport calculations (e.g., TRITON) coupled with depletion calculations for burnup. The library cross sections may be flux-weighted over the lattice to obtain data representative of the entire homogenized assembly for lumped depletion; or alternatively, it is also possible to generate multiple ORIGEN libraries corresponding to individual or groups of pins within the lattice for multi-pin depletion. The burnup-dependent ORIGEN libraries are analogous to the parameterized cross section data produced by lattice physics codes for reactor core simulators, except that data for many more nuclides and reactions are included to allow ORIGEN to compute detailed isotopics for more than 2200 nuclides.
ORIGAMI extends the capabilities previously provided by ORIGEN-ARP to perform a suite of ORIGEN calculations in order to represent the isotopic distribution of fuel within an assembly in more detail. The pre-generated ORIGEN libraries provided with SCALE tabulate the assembly-average one-group cross sections, in order to accurately reproduce assembly-average isotopics. When performing pin-by-pin calculations in ORIGAMI, users can increase the fidelity with respect to proximity to features such as assembly edges, water holes, burnable poison rods, etc. by creating and employing zone-specific libraries for different pins. By specifying the individual library assignments for each pin, users can capture these local spectrum changes in the ORIGAMI calculation through the use of one-group libraries based on these local conditions. Currently, the specification of individual libraries is limited to pin-level specification only (i.e., the same library is used for all axial zones corresponding to a pin for 3D cases) with an allowed axial moderator density distribution and radial and axial power distributions.
ORIGAMI can produce the following output files in addition to the standard ORIGEN output for each depletion zone:
isotopics in ORIGEN binary concentration (ft71) files
in each depletion zone at times specified by the options block,
ft71
keyin each axial zone (summed over all pins at a particular axial level) at the final time;
nuclide concentrations by axial zone, written as a SCALE “standard composition block” that can be used directly as input for SCALE transport codes such as the KENO Monte Carlo criticality code;
axially-dependent decay heat source for input to a thermal analysis code such as COBRA, so that the temperature distribution within a storage cask can be computed;
nuclide concentrations for each axial zone, given in the format of MCNP material cards;
space-dependent radiation source energy spectra and magnitudes in a simple text file.
ORIGAMI is tightly integrated with the SCALE Graphical User Interface, Fulcrum. Using Fulcrum and the “UO2 express form (configurable)”, one can create a simple UO2 assembly depletion case in seconds (see Fig. 5.4.1). Finally, ORIGAMI has the ability to perform the depletion/decay calculations for each zone in parallel using the MPI (Message Passing Interface), however this requires a special SCALE installation built with MPI in order to do so [ORIGAMISHDLG13].
5.4.3. Computational Methods
5.4.3.1. ORIGAMI assembly model
The basic model for ORIGAMI is a fuel assembly, which may be modeled in several ways with varying degrees of complexity. The most primitive model represents the assembly materials as a single mass lump that is depleted using the value of the specific power input in the power-history block. In this case, a single ORIGEN calculation is performed to obtain isotopics representing the entire assembly. This 0D model is equivalent to the current ORIGEN-ARP procedure. A more detailed model applies an input axial power profile to the (radially) lumped assembly materials. This lumped axial depletion model produces a 1D axially varying burnup distribution, but no allowance is made for variations in the relative pin powers within the assembly. Thus, if the axial power distribution is defined by NZ axial zones, ORIGEN calculations are performed for NZ different depletion regions. The 1D axial depletion model has been found to be adequate for most criticality and decay heat analysis of spent fuel assemblies [ORIGAMIRGlW12]. Note that both the 0D and 1D modes are fully consistent with the 2D TRITON calculations used to generate ORIGEN reactor libraries distributed with SCALE, in that these modes employ spatially-homogenized cross-sections to represent assembly-averaged flux and cross-sections. For 2D and 3D depletion models (wherein individual pin-specific libraries may optionally be specified), the user is advised that the ORIGEN reactor data libraries distributed with SCALE are representative of an assembly axial plane as a whole; in as much, the user is advised to generate their own zone-specific libraries (i.e., based on individual material zones) within TRITON if they wish to capture regional neutronic effects within the assembly (such as proximity to water holes, burnable absorbers, etc.)
By specifying a radial pin-power map, a 2D or 3D calculation may be performed. Currently the axial and radial power shapes are fixed for the entire calculation but do still result in a fully 3D isotopic distribution [ORIGAMISGRT12, ORIGAMISHDLG13]. If there are NP pins in the assembly and each has NZ axial zones, ORIGAMI will perform ORIGEN calculations for NP \(\times\) NZ depletion regions. For example, an assembly with a 17 \(\times\) 17 array with 264 fuel pins and NZ = 24 axial zones requires 6336 independent ORIGEN calculations. For these types of simulations, the parallel mode with MPI is highly recommended.
5.4.3.2. Definition of initial composition
The initial mass in metric tons of heavy metal is Mmtu, set by the
input parameter mtu
. The default value of mtu
is equal to 1.0, so
that by default the ORIGEN calculations are performed on the basis of
“per metric ton of heavy metal”. Given that the sum over all zones must
have the total heavy metal content (Mmtu), one arrives at zone-wise
heavy metal masses of:
where the relative amount of heavy metal in each radial position, :mxy, is calculated from the mixture specification; fractional axial height, fz, from the zone specification; and NP and NZ are the total number of fuel pins and axial zones, respectively. Note that some pin locations in the assembly may not contain fuel, and these are not included in the value of NP. The fractional axial height is given
\(f_z = \frac{\Delta Z }{Z_{\text{tot}}}\) is the fraction of the active fuel height occupied by axial zone Z \(\Delta Z\) is the length of axial zone
Ztot is the total length of the active fuel.
Whenever an axial zone mesh is input (with array meshz
), the value of
fZ is computed from the values of the zone boundaries (see input
description in Sect. 5.4.4.6). If an axial mesh array
is not input, the axial zones are assumed to be uniformly distributed. In this
case, the axial zones all have the same height, so that \(f=\frac{1}{N_Z}\),
where NZ is the number of uniform axial zones in the assembly.
The uranium mass in a single axial zone for all NP fuel pins in the assembly (Mz) is thus:
In addition to the fuel mixture in an assembly, non-fuel materials
(e.g., structural materials) may also be present. These materials
contribute to the overall power production due to the energy produced by
neutron capture reactions.. For a given value of the total assembly
power, this reduces the power from the fuel mass and thus may slightly
alter the fuel burnup and isotopics. In addition, activation of non-fuel
materials produces additional radiation source terms in the spent fuel,
which contribute to the decay heat and activity. Therefore ORIGAMI
provides an option for including the non-fuel elements in the input
array, nonfuel
. The units of the non-fuel element masses are kg per
MTU, and the materials are distributed uniformly within all fuel
depletion zones. Note that the input non-fuel materials should not
include oxygen in UO2 if UO2 is specified as the fuel
material, as oxygen is already included in proportion to the uranium
mass basis. Finally, because ORIGAMI accesses the StdComp library, any
SCALE StdComp composition, e.g. “zirc4” for reactor cladding material
Zircaloy-4, may be used in either structural or fuel materials.
5.4.3.3. Restart cases
ORIGAMI also allows the initial nuclide concentrations to be obtained
from a previously produced ORIGEN binary output file. A restart case is
indicated by setting restart=yes in the parameter array. The restart
file has the name assembly_restart.f71
and must be copied (or linked)
to the SCALE temporary directory used for calculations. The restart file
is normally obtained from an earlier ORIGAMI calculation, which always
produces an ORIGEN restart file named $OUTBASENAME.assm.f71
, where
${OUTBASENAME}
is an output prefix defined by the name of the input file
and any user-specified prefix with the prefix key. Generally the
restart file from ORIGAMI contains stacked concentrations, corresponding
to each axial zone and then a final entry for the lumped assembly
concentrations; hence, the initial composition for a restart case varies
with axial zone, unlike the case for fresh fuel. ORIGAMI does not
currently allow pin-dependent restart calculations. A restart case may
be useful for performing decay-only calculations of spent fuel
inventory, using the burned fuel composition previously computed for the
assembly exposure during reactor operation. For decay-only cases, a
value for the input parameter nz
must be input in order to indicate
the number of axial depletion regions in the previous burnup
calculation.
5.4.3.4. Definition of power distribution
The radial power distribution is defined by the XY fractional pin powers in the
input array pxy
, and the axial fractional powers in the input array pz
.
The input values in arrays pxy
and pz
are normalized to unity by the code.
The fractional power for a fuel pin “XY” is designated here to be
rXY, with the normalization \(\sum_{XY = 1}^{N_{P}}r_{XY}\).
Similarly the fractional axial power for an axial zone Z is aZ,
which is normalized to \(\sum_{Z = 1}^{N_{Z}}a_{Z}\). The shapes of
both the radial XY and axial Z distributions must be obtained prior to the
ORIGAMI calculation, either from neutron transport calculations or experimental
measurements. The input distributions remain constant during the ORIGEN burn
calculations for all cycles; but in reality, the power distributions may vary
with time—for example, the initial axial power distribution tends to flatten
after a period of burnup since the higher power zones deplete the fuel faster.
For this reason it is strongly recommended to use the relative burnup
distribution (at final discharge) rather than the relative power density
distribution for the input values. The burnup shape corresponds to the
shape of the time-averaged flux distribution during the exposure period. This
ensures that the final burnup distribution matches the desired shape.
Note
When comparing depletion calculations to an equivalent case from TRITON/NEWT or TRITON/KENO, it is important to note the difference between the total system power (which will include small contributions from the recoverable energy from non-fission capture reactions by the moderator and any structural materials) with the fuel power (used for the fuel depletion calculation). Because of the small contributions to the total system power from non-fuel regions, the fuel power will likely be smaller than the total system power, as specified in the burn block.
Thus, users wishing to compare the results of an ORIGAMI calculation to an equivalent TRITON calculation should ensure that that they are using the equivalent fuel mixture power from TRITON in ORIGAMI (and not the total system power); see Sect. 3.1.6.4.4 for further details.
For a given cycle, the assembly-specific power P(SP) is equal
to the value of input variable power
, read in the power-history block
(see Sect. 5.4.4.4). The assembly-specific power has units
of megawatts per MTU (MW/MTU). Therefore, the total power produced by the fuel
assembly is:
where Ptot is the assembly total power, and \(P_{A}^{\left( \text{SP} \right)}\) is the specific power for the assembly, read from input.
The absolute power (MW) in fuel pin “XY” is:
and the power produced in axial zone Z of this fuel pin XY is:
The absolute power produced in a single axial zone Z for all pins is:
The ORIGEN depletion calculations are performed with the absolute powers defined in Eq. (5.4.4) and Eq. (5.4.6) for each depletion region in the 2D/3D pin-wise or 0D/1D axial depletion models, respectively. However, cross sections in the ORIGEN libraries are parameterized as a function of burnup, which depends on the specific power rather than absolute power for a given depletion region. The specific power (MW/MTU) in axial zone Z of pin XY is equal to:
Substituting Eq. (5.4.1) and Eq. (5.4.5) into Eq. (5.4.7) gives:
In a similar manner, it can be shown that the specific power for all fuel pins in axial plane Z is:
ORIGAMI permits two modes for user-specified power distributions along the axial and radial meshes: absolute fractions (i.e., where powers along the axial mesh points are expressed as fractions of the total assembly power in MW) and relative normalization (i.e., in which specific powers— in MW/MTU — of axial zones are expressed as a relative modifiers of the assembly specific powers input in the power history block). Relative power shape modifiers assume that the specific powers expressed in the power history block represent the average assembly specific power(s) thus, ORIGAMI will convert these factors into axial & pin power fractions — i.e., the factors rxy and az found in Eq. (5.4.4) and Eq. (5.4.6) used to calculate the absolute pin power and axial zone power, respectively. The conversion from relative specific power modifiers to absolute power fractions is accomplished through the following normalization procedure Eq. (5.4.10):
where \(\left( a_{Z} \right)_{i}\) is the axial power fraction for axial zone i and \(\left( R_{Z} \right)_{i}\) is the relative axial zone specific power modifier for axial zone i. Obviously, for a uniformly-spaced axial mesh, the conversion from relative specific powers (using relative power modifiers) is precisely the same as that for absolute fractional axial zone powers; i.e., the relative power modifiers simply become axial power fractions by virtue of the fact that the term \(\left( \frac{\Delta Z}{Z_{\text{tot}}} \right)_{i}\) becomes a constant, thereby reducing Eq. (5.4.10) back to a direct calculation of the fractional axial power based on a relative power modifier following normalization.
Because it is assumed that the assembly mass is uniformly distributed across the pins, it can similarly be shown that the use of relative power modifiers for the XY pin map \(\left( r_{XY} \right)_{i}\) will always produce the same result as using pre-normalized absolute fractional powers in the pin map, i.e. Eq. (5.4.11):
(5.4.11)\[\left( r_{XY} \right)_{i} = \frac{\left( R_{XY} \right)_{i} \cdot \frac{M_{\text{MTU}}}{N_{P}}}{\sum_{}^{}{\left( R_{XY} \right)_{i} \cdot \frac{M_{\text{MTU}}}{N_{P}}}} = \frac{\left( R_{XY} \right)_{i}}{\sum_{}^{}\left( R_{XY} \right)_{i}}\]
This option is provided as the relnorm
option in the parameters block
(discussed further in Sect. 5.4.4.2). The motivation
for providing an alternative normalization for axial power shape factors is
twofold. First, it is generally assumed that information on the axial power
shape is obtained from axial measurements relative to an assembly-average
value (i.e., axial gamma scans to determine the burnup profile based
upon the gross gamma intensity or isotopic ratios of burnup indicators
such as 134Cs / 137Cs, etc.). Therefore, by using the
relative normalization option (i.e., treating axial power shape factors
as relative modifiers of the assembly specific power), users can
directly input shape factors obtained from techniques such as
non-destructive analysis (NDA) fuel measurements into ORIGAMI to model
assembly isotopic distributions.
The second motivation for the relative normalization option comes from potential problems that can arise if treating axial power shape factors as absolute fractional powers (relnorm=no) in conjunction with non-uniform axial mesh spacing defined by the user in the z array (see Sect. 5.4.4.7 for details).
Important
If using the relnorm=no option, the fractional axial powers must be consistent with the axial mesh sizes defined or else incorrect zone-specific powers will result from Eq. (5.4.9), therefore leading to incorrect results and likely causing the ARP sequence to fail (and therefore the ORIGAMI calculation to halt) due to calculated burnup values for the depletion zone being out of the library range.
Users are thus strongly cautioned when using absolute fractional axial powers (relnorm=no) to ensure proper consistency between the axial power fractions and the axial mesh sizes.
For this reason, relative power shape factor normalization is turned on by default (relnorm=yes).
5.4.3.5. Computation of neutron and gamma energy spectra
ORIGAMI includes an option to generate multi-group neutron and gamma
source spectra due to radioactive decay, for each depletion zone.
Multi-group values are calculated by binning the discrete line and
continuum spectra produced by radioactive decay and nuclear reactions
into arbitrary energy group structures defined by user input. Whenever
neutron energy group boundaries are input in array ngrp
, neutron
source spectra due to spontaneous fission, delayed neutron emission, and
\(\left( \alpha, n\right)\) reactions are calculated.
Similarly, gamma source spectra are computed if gamma energy group bounds are
input in array ggrp
. The gamma source includes photons produced by all types
of radioactive decays, and also may include bremsstrahlung radiation produced
by beta interactions. Input options can specify the type of nuclides included in
the source term (i.e., light elements, actinides, fission products, or all
nuclides), and the materials used for \(\left( \alpha,n \right)\)
reactions and bremsstrahlung production. If source spectra are calculated, the
values are always included in the ORIGEN output ft71 binary file; and
optionally the source spectra may also be output in a text file. The source
text file only includes the average over all pins for each axial zone, while
the ft71 file includes sources for all pins and axial zones.
The source spectra output by ORIGAMI are calculated in ORIGEN using the expression outlined in Eq. (5.4.12):
where
\(S_{\text{Z.g}}^{(p)}\) = source spectrum (p/s) in energy group g for particles of type p and axial zone Z;
\(Y_{i,g}^{(p)}\) = number of particles of type p emitted per decay of nuclide i; with energy in group g;
\(M_{Z}^{(i)}\) = mass (g) of nuclide i in axial zone Z, obtained from ORIGEN calculation;
NA = Avogadro’s number (number atoms of nuclide i per mole);
A(i) = mass (g) of 1 mole of nuclide i;
\(\lambda_i\) = decay constant (s-1) for nuclide i,
itot = total number of nuclides in burned fuel.
More details on the ORIGEN calculation of the source spectra can be found in the ORIGEN section (Sect. 5.1.5.2.5.2) of the SCALE documentation.
5.4.4. ORIGAMI Input Description
ORIGAMI uses free-form, keyword-driven input with the SCALE Object Notation (SON) syntax also used for ORIGEN input, and is described in more detail there. The general outline of ORIGAMI input is as follows.
Case Identifier
Options
Fuel Composition
Power-History
Source-Options
Output-Print Options
Input Data
The above input data may be entered in any order. Data blocks and parameters which are not needed, or for which default values are desired, can be omitted. Example 5.4.1 provides a template containing all of the ORIGAMI input data blocks and arrays, with example values assigned. Note that much of the information shown in the template is optional, and typically is not needed for many cases. The following subsections provide a more detailed description of the input.
=origami
% Case identifier information
title= 'input template example'
prefix= example
asmid=1
% Parameter options
options{
pitch= 19.718
mtu= 0.4
decayheat=yes
fracnf=0.08
nburn=15
ndecay=12
temper=300.0
stdcomp=yes
restart=no
interp=spline
output=cycle
ft71=all
}
% Array containing ORIGEN library names
libs=[ ce14x14 ce16x16 ]
% Fuel Composition
fuelcomp{
uox(fuel1){ enrich=3.21 }
uox(fuel2){ enrich=3.50 }
uox(fuel3){ enrich=2.80 }
mix(1){ comps[ fuel1=98.2 Gd2O3=1.8 ] }
mix(2){ comps[ fuel2=100 ] }
mix(3){ comps[ fuel2=97.5 Gd2O3=2.5 ] }
mix(4){ comps[ fuel3=96.9 Gd2O3=3.1 ] }
}
% Map ORIGEN library names to XY pin layout
libmap=[ 1 2
2 1 ]
% Map individual compositions XY pin layout
compmap=[ 1 2
3 4 ]
% XY relative power distribution (code renormalizes to unity)
pxy=[ 0.2 0.3
0.4 0.5 ]
% Z-axial relative power distribution (code renormalizes to unity)
pz=[ 0.6 0.4 ]
% Axial interval boundaries (for MTU mass distribution & plotting)
meshz=[ 0.0 15.0 30.0 ]
% Non-fuel nuclides distributed within fuel material
nonfuel=[ cr=3.366 mn=0.1525 fe=6.309 co=0.0302
ni=2.366 zr=516.3 sn=8.412 gd=2.860 ]
% Axial variation of moderator density fraction
modz=[ 0.73 0.715 ]
% Irradiation/decay information
hist[
cycle{ power=35.0 burn=200.0 nlib=7 down=50.0 }
]
% Optional neutron/gamma source information
ggrp=[ 10.0e6 2.0e6 1.0e6 0.5e6 0.01 ]
ngrp=[ 20.0e6 1.0e6 1.0e5 1.0e4 1.0e3 10.0 0.01 ]
srcopt{ sublib=ac brem_medium=uo2 alphan_medium=case print=yes }
% Output edit options
print{
nuc{sublibs=[lt ac] total=no units=[grams] }
}
% Nuclides included in comp file (OPTIONAL: overrides default)
nuccomp=[
92232 92233 92234 92235 92236 92237 92238 92239 92240
92241 93235 93236 93237 93238 93239 94236 94237 94238
94239 94240 94241 94242 94243 94244 94246 95241 95242
95243 95244 95246 96241 96242 96243 96244 96245 96246
96247 96248 96249 96250 97249 97250 98249 98250 98251
98252 98253 98254 99253 99254 99255
]
end
5.4.4.1. Case and identifier information
ORIGAMI has three optional identifiers for the case. The title
is
included as a descriptor in the printed output file. The character string
prefix
is added to the front of the output file names described in
Sect. 5.4.5 and in Table 5.4.8. Finally,
the integer variable asmid
is an arbitrary assembly identifier used
in defining mixture numbers in the SCALE standard composition output file.
Eq. (5.4.14) in Sect. 5.4.5.1 describes how
the mixture ID is determined.
- title= <string>
Title (up to 50 characters) describing the case. Enclosed in quotes if using embedded blanks.
(Default: none)
- prefix= <string>
Prefix (up to 16 characters) to append to output file names.
(Default: none)
- asmid= <integer>
Integer used to identify mixture ID in generated SCALE standard composition block [see Eq. (5.4.14)].
(Default: 1)
Keyword |
Description |
Default |
---|---|---|
title= |
up to 50 characters describing the case title, quoted if embedded blanks |
blank |
prefix= |
up to 16 characters (no embedded blanks) appended to output file names |
blank |
asmid= |
integer used to identify mixture ID in generated SCALE standard composition block [see Eq. (5.4.14)] |
1 |
5.4.4.2. Options block
The options
block has the following form:
- options {… keyword blocks …}
The
options
block allows the user to control problem features such as the total mass basis (mtu
), non-fuel mass (fracnf
), axial power normalization (relnorm
), exercise fine-grained control over depletion calculations (solver
,interp
, option:nburn,ndecay
), perform restart calculations from a prior ORIGAMI run (restart
), specify the number of axial zones (nz
), specify optional parameters used for visualization and post-processing (pitch
,temper
,fdens
), and control which outputs to generate (small
,mcnp
,stdcomp
,decayheat
).
Each of the allowable parameter keywords is explained below. An example parameter block would be:
options{ stdcomp=yes decayheat=yes }
- mtu= <number>
Metric tons of heavy metal in the assembly.
(Default: 1.0)
- fracnf= <number>
Total non-fuel mass in the assembly, given as a fraction of the heavy metal mass defined in
mtu
.(Default: none)
- nz= <integer>
Number of axial intervals. If not input,
nz
is equal to the number of entries in the input axial power arraypz
.Required for decay-only restarts.
(Default: Determined by code via
pz
)
- nburn= <integer>
Number of substeps used in ORIGEN burn calculations
(Default: 10)
- ndecay= <integer>
Number of substeps used in ORIGEN decay calculations
(Default: 10)
- pitch= <real number>
Assembly pitch (cm), if > 0.0. Only used to define XY mesh in viewing results. If this parameter is input, array
pxy
must also be entered.(Default: 0.0)
- temper= <real number>
Temperature (in degrees Kelvin) for mixtures output to the SCALE Standard Composition output (
compBlock
).(Default: 293.0)
- fdens= <real number>
Fuel density in g/cm3. Used to calculate the effective fuel volume based on the total mass basis (thus facilitating conversion to volumetric units of concentration, such as atoms/bn-cm). Used in calculating atom densities for the SCALE Standard Composition output (
compBlock
).(Default: 10.4)
- offsetz= <integer>
Axial numbering offset; used for sequential ORIGAMI cases to uniquely identify axial zones (i.e., such as when using sequential cases to modify changing axial geometry).
(Default: 0)
- relnorm= <yes | no>
Normalization of axial power shaping factors (
pz
) to be used- no → axial power shape factors treated as absolute fractions (does
not normalize all axial burnups to 1.0)
- yes → axial power shape factors treated as relative modifiers of
assembly specific power (i.e., power= entries in the power history block)
(Default: yes)
- mcnp= <yes | no>
Generate MCNP input stubs containing data on material concentrations and/or gamma and neutron emissions for each depletion node in the problem.
(Default: yes)
- stdcomp= <yes | no>
Generate a text-based standard composition file containing burnup-credit nuclide number densities for each axial zone.
(Default: no)
- decayheat= <yes | no>
Produce a decay heat file containing decay powers (in W) for each axial zone.
(Default: no)
- restart= <yes | no>
Perform a restart calculation using initial compositions from a previously-generated ORIGEN ft71 file.
(Default: no)
- solver= <matrex | cram>
Use the standard (“MATREX”) solver or the Chebyshev Rational Approximation Method (CRAM) solver.
(Default: matrex)
- small= <yes | no>
keep .out file small by suppressing all spectra and concentrations output except for lumped, assembly-averaged concentrations and spectra
Note
Full results are still written to other relevant files
(Default: no)
- interp= <lagrange | spline>
Method for interpolating cross sections in ARP; Lagrangian polynomial (lagrange or monotonic cubic spline spline)
(Default: lagrange)
- ft71=<last,cycle,all>, output=<last,cycle,all>
Controls output of saved / printed output concentrations.
last
saves / prints results only for the substeps in last step of the last cycle (default)cycle
saves results for substeps in the last irradiation and decay steps in every cycleall
saves results for all substeps of all irradiation and decay steps in every cycle(Default:
last
)
Keyword |
Description |
Default |
---|---|---|
mtu= |
Metric tons of heavy metal in the assembly |
1.0 |
fracnf= |
Total non-fuel mass in
assembly, given as fraction of
heavy metal mass defined by
input mtu= . See description
of input array
|
none |
nz= |
Number of axial intervals. If
not input, nz is equal to the
number of entries in the input
axial power array |
Determined by code |
nburn= |
Number of substeps used in ORIGEN burn calculations |
10 |
ndecay= |
Number of substeps used in ORIGEN decay calculations |
10 |
pitch= |
Assembly pitch (cm), if > 0.0.
Only used to define XY mesh in
viewing results. If this
parameter is input, array
|
0.0 |
temper= |
Temperature (Kelvin) assigned to materials in standard composition file |
293.0 |
offsetz= |
Axial numbering offset; used for sequential ORIGAMI cases to uniquely identify axial zones (i.e., such as when using sequential cases to modify changing axial geometry). [integer] |
0 |
relnorm= |
Normalization of axial power
shaping factors ( no: axial power shape factors treated as absolute fractions (does not normalize all axial burnups to 1.00) yes: axial power shape factors treated as relative modifiers of assembly specific power (i.e., power= entries in the power history block) [yes/no] |
Yes |
mcnp= |
no/yes → do not / do generate an MCNP material and gamma/neutron file |
Yes |
stdcomp= |
no/yes → do not / do generate a standard composition file containing burnup-credit nuclide number densities for each axial zone. |
No |
decayheat= |
no/yes → do not / do produce a decay heat file containing decay powers (in W) for each axial zone. |
No |
restart= |
no/yes → do not / do restart using initial compositions from a previously-generated ORIGEN ft71 file. |
No |
solver= |
matrex/cram → use the standard (“MATREX”) solver or the Chebyshev Rational Approximation Method (CRAM) solver. |
Matrex |
small= |
no/yes → keep .out file small by suppressing all spectra and concentrations output except for lumped, assembly-averaged concentrations and spectra (Note: all results are still written to other relevant files). |
No |
interp= |
lagrange/spline → method for interpolating cross sections in ARP |
Lagrange |
output= |
last/cycle/all → time steps for output print edits |
Last |
ft71= |
last/cycle/all → time steps included in output ft71 file |
Last |
Additional notes on input parameters:
pitch
is only used for visualization of the results, and may be omitted if this is not of interest;
mtu
is discussed in Sect. 5.4.4.2
nz
is not required except decay-only restart cases; it must equal the number of entries in the arraypz
;
nburn
andndecay
are discussed in Sect. 5.4.4.4;
fracnf
is discussed in Sect. 5.4.4.7, where the input array of non-fuel materials is described;
relnorm
is discussed in Sect. 5.4.3.4, in the definition of the assembly power distribution;
stdcomp
,fdens
, andtemper
are discussed in Sect. 5.4.5;
offsetz
is an optional feature designed to allow for ORIGAMI cases to be split across multiple inputs to capture axially-dependent features (such as partial-length rods); its use is discussed in further detail in the context of output generation in Sect. 5.4.5;
decayheat
is discussed in Sect. 5.4.5.3;
restart
is discussed in Sect. 5.4.3.3.
output
,ft71
, are discussed in Sect. 5.4.3.4.
5.4.4.3. Fuel composition block
The purpose of the fuelcomp
block is to create a set of mixtures (via
the mix blocks inside) to specify the pin-wise distribution of initial
isotopics. The example below, defines three mixtures (with IDs 1, 2, and
3); these are referenced in the compmap
array for this 2x2 array of
fuel pins.
- fuelcomp= { mixture blocks }
Specifies fuel mixtures to be used by ORIGAMI in the
compmap
array. Numberedmix
blocks are used bycompmap
, which can be composed of other named mixtures.
- mix= { SCALE standard composition }
Mixture blocks identify specific pin-wise composition to be used by ORIGAMI, using the standard SCALE mixture composition syntax. Mixtures must be given an integer identifier (e.g.,
mix(1)
,mix(2)
, etc.)
- compmap= [ mixture IDs ]
Specifies the distribution of fuel compositions / mixtures for each pin for 2-D and 3-D depletion cases. Mixture ID numbers correspond to those in the
fuelcomp
block.Required if
libmap
is explicitly specified beyond one element.(Default:
[1]
)
fuelcomp{
uox(fuel_3pct){ enrich=3.20 dens=10.42 }
uox(fuel_4pct){ enrich=4.00 dens=10.45 }
uox(fuel_2pct){ enrich=2.10 dens=10.43 }
mix(1){ comps[ fuel_3pct=99.0 Gd2O3=1.0 ] }
mix(2){ comps[ fuel_4pct=100] }
mix(3){ comps[ fuel_2pct=100] }
}
compmap=[ 1 2
2 3 ]
The mix block defines an array of compositions by their weight %. For example, in the case of mix 2 and 3, it is 100% the “fuel_4pct” and “fuel_2pct” compositions defined on the uox blocks above. In the case of mix 1, it is 99% by weight fuel_3pct and 1% by weight the SCALE StdComp Gd2O3 (gadolinia). Each mixture number (defined by numbered mix objects) is then referenced in the compmap array to define an individual pin composition. For UOx-based fuels, ORIGAMI automatically calculates the pin enrichment for cross-section library interpolation via ARP. (Interpolation for MOX-based fuels is not supported by ORIGAMI at this time.)
The uox keyword is an ORIGAM-specific shortcut to allow for easy specification of UO2-based fuels along with their enrichment; ORIGAMI automatically expands the uox keyword into a SCALE StdComp block with a UO2 base and explicitly-calculated uranium isotopics per Table 5.4.3. For example, the uox block “fuel_3pct”expands to the following (Example 5.4.3):
stdcomp(fuel_3pct){
base=uo2
iso[92234=0.02848 92235=3.2 92236=0.01472 92238=96.7568]
}
For uox-based entries, the uranium isotopic distribution is calculated from the user-specified enrichment per the formula outlined in Table 5.4.3 [ORIGAMIOWHR94, ORIGAMIRGI10]:
Isotope |
Isotope wt% |
---|---|
234U |
0.0089 X |
235U |
1.0000 X |
236U |
0.0046 X |
238U |
100 - 1.0135 X |
Users may also specify materials directly using SCALE mixture processor conventions; for example, the user could simply enter fuel mixture 2 directly as a StdComp as shown in Example 5.4.4 and Example 5.4.5:
mix(2){
stdcomp(fuel_4pct){
base=uo2
iso[92234=XXX 92235=XXX 92236=XXX 92238=XXX]
}
}
Or similarly, one can refer to a composition by its alias:
stdcomp(fuel_4pct){
base=uo2
iso[92234=XXX 92235=XXX 92236=XXX 92238=XXX]
}
mix(2){ comps[ fuel_4pct=100.0 ] }
The uox keyword is thus useful when a user wishes to quickly specify a UO2-based fuel; however, in cases where the user wishes to specify the isotopic fractions of each uranium isotope, the use of a StdComp object is recommended.
Caution
The mixture composition system in ORIGAMI is very flexible but the user is cautioned that ORIGAMI does not rigorously check that the specified composition is neutronically similar to that used to generate the ORIGEN library used in the calculation.
For example, use of gadolinia burnable absorbers in the ORIGAMI input will yield incorrect results if the ORIGEN library was generated without gadolinia, due to the extreme thermal flux depression that gadolinia creates. It is therefore up to the user to verify that the libraries specified for the depletion zone are matched neutronically to the compositions specified.
5.4.4.4. Power history block
The data contained in the power history block is the same as in the BURNDATA block of the TRITON lattice physics depletion sequence in SCALE (see the TRITON chapter, BURNDATA block). The power-history block describes the burnup and decay of the assembly and has the following general form:
hist[
cycle{ keywords for cycle-1 }
cycle{ keywords for cycle-2 }
… *(repeat for total number of cycles) …*
]
Because the cycles must be processed in order, the array syntax with “[]” is used for the “hist” block. (The block syntax “{}” implies no order for its contents.) The “hist” array consists of one or more “cycle” blocks, each describing the assembly irradiation and/or decay for some period of time. Each cycle is defined by (a) the assembly total specific power; (b) number of exposure days at this power; (c) the number of ORIGEN library burnup interpolations during the exposure period; and (d) number of days of decay following the exposure period.
The keywords defining this information are:
- power= <real number>
Assembly specific power (MW/MTU) for the cycle
(Default: 0.0)
- burn= <real number>
Length of cycle exposure period in days
(Default: 0.0)
- down= <real number>
Downtime (decay) in days following exposure
(Default: 0.0)
- nlib= <integer>
Number of ORIGEN library burnup-interpolations during the cycle
(Default: 1)
Keyword |
Description |
Default |
---|---|---|
power= |
assembly specific power (MW/MTU) for the cycle |
0.0 |
burn= |
length of the cycle exposure period in days |
0.0 |
nlib= |
number of ORIGEN library burnup-interpolations during the cycle |
1 |
down= |
downtime in days following the exposure |
0.0 |
- 1
Keywords are repeated for each cycle.
Example 5.4.7 demonstrates the use of the power-history block for four cycles:
hist[
cycle{ power=35.6 burn=400 nlib=6 down=30 }
cycle{ power=38.2 burn=350 nlib=6 down=30 }
cycle{ power=30.0 burn=200 nlib=4 down=30 }
cycle{ down=10000 }
]
ORIGAMI discretizes time intervals first by cycles (composed of a
fixed power over a set burn time interval and / or decay time), where
each cycle is composed of a number of substeps. The power-history
block, along with values of nburn
and ndecay
from the input
parameter block, define various types of nested time intervals
(substeps) for the ORIGEN calculations. The entire time period for an
ORIGAMI case is first of all divided into the cycles defined within the
power-history block. Each cycle is divided into an exposure interval
(burn
) and a decay (down
) interval. The exposure interval has a
constant specific power, but it is further subdivided into a number of
equally spaced burnup steps defined by nlib
in the power-history
block. This parameter specifies the number of burnup-dependent ORIGEN
libraries to use during the exposure interval. Cross section values for
each burnup step are interpolated using the burnup at the midpoint of
the step and remain constant throughout the burnup step. The burnup
period associated with a single ORIGEN library, or a decay period, is
called a time “step.” Finally, each burnup step, as well as the entire
decay step, is divided into a number of computational “substeps”—the
actual time steps used in the ORIGEN solver kernel. The number of
substeps in each burnup step is given by the value of nburn
, while
the number of decay substeps is equal to the value ndecay
. The
default number of substeps for both burnup and decay is equal to 10. The
substeps for irradiation are equally spaced but for decay follow the
rule of threes, i.e. each substep increases in duration by a factor of
three over the previous substep.
For the example given above, there are four cycles. The first three cycles include both exposure and decay intervals, while the last cycle is decay only. In the first cycle, the assembly-specific power is 35.6 MW/MTU, which remains constant over the 400-day exposure interval; therefore, the total burnup for the exposure period is 400*35.6 = 14240 MWD/MTU. This exposure period is divided into six burnup steps of 66.67 days, each with a cross-section library based on the midpoint burnup of that step. Thus, ORIGEN libraries are interpolated at 1186.7, 3560.0, 5933.3, 8306.7, 10680.0, and 13053.3 MWD/MTU. Each of the six burnup steps is further subdivided into 10 computational substeps. Likewise, the decay interval of 30 days is divided into 10 computational substeps.
5.4.4.5. Source options block
This block defines options used in computing neutron and gamma sources.
The block is only used if the input energy group boundary arrays ggrp
or ngrp
is given, which indicates that radiation decay source spectra
are to be computed. The general form of this block is:
- srcopt { … keyword-value pairs … }
Where the following blocks are permitted:
The following (Example 5.4.8) is an example of the
srcopt
input block:
srcopt{
sublib= …
brem_medium= …
alphan_medium= …
print= …
}
If print=yes, then text files with axial neutron and gamma sources are created.
- sublib= [ lt / fp / ac / all ]
Gamma sources from light elements / fission products / actinides / all nuclides.
(Default: all)
- brem_medium= [ H2O / UO2 / none ]
Medium for Bremsstrahlung production based on water (H2O), uranium oxide (UO2), or no Bremsstrahlung calculation (none)
(Default: UO2)
- alphan_medium= [ UO2 / borosilicate / case ]
Target medium used for \(\left(\alpha,n\right)\) source caclulation; UO2, borosilicate glass, or case-specific mixture.
(Default: case)
- print= [ yes / no ]
Write text-based output file containing source information / only write radiation source terms to binary ft71 file.
(Default: no)
Keyword |
Description |
Default |
---|---|---|
sublib= |
lt / fp / ac / all → gamma sources from: light elements / fission products / actinides / all nuclides |
all |
brem_medium= |
none / H2O / UO2 / → bremsstrahlung production based on: no bremsstrahlung / water / UO2 |
uo2 |
alphan_medium= |
UO2 / borosilicate/ case → (alpha,n) source computed for: UO2/ borosilicate glass / case-specific mixture |
case |
print= |
yes / no → write output text file containing sources / only write sources in binary output ft71 file |
no |
5.4.4.6. Output print-options block
This block defines the desired ORIGEN output response edits to be printed by ORIGAMI.
The following is an example input which edits response values for the mass in grams, activities in Curies, and concentrations in atoms/barn-cm, for all nuclides (isotopes) broken down by actinides or fission products as well as curies by element, totaled over all nuclide sub-libraries (sublibs).
print{
nuc{ units=[grams curies atoms-per-barn-cm] sublibs=[fp ac] }
ele{ units=[curies] total=yes }
}
- nuc= { }, ele={ }
Block to specify print options for output by individual nuclides / elements
- units= [ moles / gram-atoms / grams / curies / becquerels / watts
- / g-watts / m3_air / m3_water / weight_ppm / atoms_ppm / atoms-per-barn-cm ]
Output concentrations in units of gram-atoms (moles), grams, curies, becquerels, total thermal power (alpha, beta, and gamma), thermal power from gammas only, radiotoxicity / dilution factors for air and water, mass fraction (in ppm), atom fraction (in ppm), atoms / barn-cm 2, respectively.
One or more output units may be specified, separated by commas.
(Default: gram-atoms)
- 2
Requires volume input
- sublibs= [ le / fp / ac / all ]
Output concentration units for light element sublibrary, fission product sublibrary, actinide sublibrary, or all nuclides.
(Default: all)
- total= [ no / yes ]
Print out total concentration for nuclides / elements for each selected unit type.
(Default: yes)
Keyword |
Description |
Default |
---|---|---|
nuc / ele |
Specify print options for output by individual nuclides / elements |
N/A |
units= |
moles / gram-atoms / grams / curies / becquerels / watts / g-watts / m3_air / m3_water / weight_ppm / atoms_ppm / atoms-per-barn-cm Output concentrations in units of gram-atoms (moles), grams, curies, becquerels, total thermal power (alpha, beta, and gamma), thermal power from gammas only, radiotoxicity / dilution factors for air and water, mass fraction (in ppm), atom fraction (in ppm), atoms / barn-cm, respectively. |
all |
sublibs= |
le / fp / ac / all → output concentration units for light element / fission product / actinide sub-libraries |
all |
total= |
yes / no → print out total concentration for nuclides / elements for each output unit type |
yes |
5.4.4.7. Input data arrays
For all other input arrays in ORIGAMI, the input values are entered in either
of the general forms (with or without =
):
array[ … values … ]
array=[ … values … ]
The array libs
, which defines the ORIGEN library files, is the only
one that is strictly required for all cases. Cases that simulate 0D or
1D lumped-assembly models typically only require one entry for a single
ORIGEN library (assuming uniform axial enrichment), while the simulated
3D depletion model may utilize multiple libraries if specific ORIGEN
libraries are pre-generated for different pin locations (e.g., adjacent
to a water hole, Gd rods, etc.). If multiple libraries are used, the
array libmap
is required to identify the pin locations associated
with the input libraries. The numbering of these libraries in the libmap
array corresponds to the ordering of libraries in the libs
array;
i.e., a “1” corresponds to the first library specified, “2” to the
second, and so on. A zero-value entry in the array indicates that the
location is not to be depleted (i.e., a non-fuel region, such as a water
hole or guide tube).
For single array values, the array bracket syntax is not required. For example, each of the following is equivalent:
compmap=[1]
compmap[1]
compmap=
Note that the assignment operator (=
) is likewise optional for arrays
when using the square-bracket syntax.
Unless the 0D lumped-assembly model (i.e., lumped mass with no axial
power variation) is used, at least one of the arrays (pz
,
pxy
) describing the power variations must also be entered. The 1D
axial depletion model requires that the pz
array be entered, while
the pin-wise depletion model additionally requires the array pxy
.
The data in arrays pxy
and pz
correspond to the variables
rxy and az, respectively, described in
Sect. 5.4.3.4. The axial and XY power distributions are
normalized to unity inside the code, so that only the ratios of the input
array values are significant. As discussed in Sect. 5.4.3.4,
it is generally recommended to use the final burnup distributions rather than
the relative power distributions for the values in the pxy
and
pz
arrays.
The array nuccomp
defines the nuclides to be included in the output
compBlock file, described in more detail in Sect. 5.4.5.
The nuclides in the array are identified by their seven digit IZZZAAA
identifier defined as ID = I * 1000000 + Z * 1000 + A, where Z is the atomic
number; A is the mass number, and I is the isomeric state (I=0 for ground; I=1
for first metastable; etc.). For example, identifiers for 16O and
242mAm are 8016 and 1095242, respectively. If this array is
omitted, the nuclides in Table 5.4.9 are used.
This is described in more detail in Sect. 5.4.5.1.
The optional array describing the non-fuel elements in the assembly contains pairs of values (element, mass), where “element” is the chemical symbol for a particular element, and “mass” is the mass of the element in kilograms per MTU. For example, the:
nonfuel=[ zr=520.3 sn=8.4 ]
indicates that the assembly contains 520.3 kilograms of zirconium and
8.4 kilograms of tin for each metric ton of uranium (MTU) in the
assembly. Note that elemental masses are specified — the isotopic masses
are computed internally by the code using natural abundances in the data
library. It is also possible to normalize the total mass of non-fuel
elements to a specified fraction of the MTU mass using the parameter
fracnf
in the parameter block. In this case, only the relative
amounts of each non-fuel element are needed for the nonfuel
array.
Non-fuel masses are distributed uniformly among all the fuel depletion
regions.
- libs= [ ... ]
List of ORIGEN one or more library file names for fuel in assembly
Required
- libmap= [ integer(s) ]
XY map of library identifiers associated with each pin in assembly. Library identifiers correspond to the order of the ORIGEN libraries entered in the
libs
array (i.e., index positions)(Default:
[1]
)See also
- commap= [ integer(s) ]
XY map of mixture identifiers that correspond to the mixture ID in the fuelcomp block.
(Default:
[1]
)See also
- pxy= [ real number(s) ]
XY map of pin power shaping factors / fractional powers. Must be a square array (e.g., 15×15). Defaults to lumped assembly model (no individual pins).
(Default:
[1.0]
)
- pz= [ real number(s) ]
Axial (Z) power shaping factors / fractional power distribution for the assembly.
(Default:
[1.0]
)
- meshz= [ real number(s) ]
Axial mesh boundaries (cm) for the axial relative power zones. Only required to define axial mesh for viewing results; but if entered, it must be consistent with axial power shape. The number of entries should be one greater than number of entries in
pz
array.(Default: none)
See also
- modz= [ real number(s) ]
Axial variation in water density (g/cc) corresponding to the axial power zones.
(Default:
[0.723]
)
- nonfuel= [ key-value pairs ]
Non-fuel materials contained in assembly. Values are entered in pairs of
element-symbol=mass
(kg per mtu of HM ). If parameterfracnf
is input, mass of non-fuel materials is normalized to this fraction of fuelmtu
.Note
Oxygen mass in UO2 should not be entered here (i.e., this is pre-supplied by ORIGAMI).
(Default: None)
- ggrp= [ real numbers ]
Energy boundaries (eV) for defining decay gamma source spectrum, in monotonically increasing order.
(Default: None)
- ngrp= [ real numbers ]
Energy boundaries (eV) for defining \(\left(\alpha,n\right)\) and fission neutron source spectrum.
(Default: Nuclides in Table 5.4.9)
- nuccomp= [ IZZZAAA values ]
User-specified list of nuclides (in IZZZAAA format) to be included in the
compBlock
file.(Default: Nuclides specified in Table 5.4.9).
Array Name |
Description |
Default |
---|---|---|
libs * |
List of ORIGEN library file names for fuel in assembly. [characters] |
None |
libmap |
XY map of library identifiers associated with each pin in assembly. Library identifiers correspond to the order of the ORIGEN libraries entered in the libs block. [integers] |
1 |
compmap |
XY map of mixture identifiers that
correspond to the mixture ID in
the |
1 |
pxy |
XY map of pin power shaping factors / fractional powers. Must be a square array (e.g., 15×15). Defaults to lumped assembly model (no individual pins). [real numbers] |
1.0 |
pz |
Axial (Z) power shaping factors / fractional power distribution for the assembly. [real numbers] |
1.0 |
meshz |
Axial mesh boundaries (cm) for the
axial relative power zones. Only
required to define axial mesh for
viewing results; but if entered,
it must be consistent with axial
power shape. The number of entries
should be one greater than number
of entries in |
None |
modz |
Axial variation in water density (g/cc) corresponding to the axial power zones. [real numbers] |
0.723 |
nonfuel |
Non-fuel materials contained in assembly. Values are entered in pairs of (element-symbol=mass(kg) per mtu of HM ). If parameter fracnf is input, mass of non-fuel materials is normalized to this fraction of fuel mtu. NOTE: Oxygen mass in UO2 should not be entered here (i.e., this is pre-supplied by ORIGAMI). [character / real number pairs] |
None |
ggrp |
Energy boundaries (eV) for defining decay gamma source spectrum. [real numbers] |
None |
ngrp |
Energy boundaries (eV) for defining \(\left(\alpha,n\right)\) and fission neutron source spectrum. [real numbers] |
None |
nuccomp |
List of nuclide IZZZAAAs to be included in output compBlock file. |
Nuclides |
* indicates required |
5.4.5. ORIGAMI Input/Output Files
Table 5.4.8 gives the input and output files for ORIGAMI.
ORIGAMI produces printed output results as well as several optional output
files described in this section. In order to reduce the potentially voluminous
amount of printout, by default ORIGAMI only prints the concentrations in
grams for selected actinides in each axial zone of every pin, and only
for the last time step (e.g., decay step) of the last cycle in the
power-history block. Time-dependent results are given for all substeps
in the last step (i.e, there are nburn
and ndecay
substeps within a
burn step or decay step, respectively) In addition, the blended actinide
concentrations over all pins are printed for each axial zone, and for
the entire lumped assembly. Additional types of printed output can be
specified in the print
block. The concentrations, as well as optional
neutron and gamma source spectra information, for all nuclides, in all
pins and axial zones are also stored in the ORIGEN binary output file,
often called an “ft71” file. The contents and format of the binary file
are described in the ORIGEN documentation of the SCALE manual. The
binary file information can be edited by the OPUS module in SCALE. Like
the printed output, the ft71 file is written by default only for the
last step of the last cycle. However, both the printed output and binary
file results can be obtained at additional time steps by specifying the
input variables output and ft71, respectively, in the OPTIONS input
block. These input parameters can have the keywords:
The output files are written in the user output directory for the
calculation (i.e., the same directory where the printed output file is
written — the default is the directory from where the case was
submitted). File names are prefixed by an extension consisting of the
input file base-name appended to an optional character string given by
the input keyword prefix
. For example, if the ORIGAMI input file is
named file:ORIGAMICase.inp, the base-name is ORIGAMICase
. Thus, if the
keyword prefix
is not included in the input, the file containing the
axial decay heat results is named file:ORIGAMICase_AxialDecayHeat. On the
other hand, if the input contains the keyword prefix=CE16X16, the file
is named ORIGAMICase_CE16X16_AxialDecayHeat
.
In order to capture axially dependent features of an assembly (such as
partial-length rods), users may elect to construct sequential ORIGAMI
cases that modify the XY pin map features (e.g., library and enrichment
maps) between cases. In order to allow for these types of “continuation”
cases (in which the sequential case represents an adjacent axial span of
the assembly), the offsetz
feature is provided, which adjusts the
axial numbering for ORIGAMI outputs (such as for MCNP materials &
spectra cards, axial decay heat, etc.). The offsetz
parameter offsets
the axial numbering for these output files, where the (integer) value
provided corresponds to the last axial zone number calculated by
ORIGAMI (default: 0). For more details on the syntax of the options
block, see Sect. 5.4.3.4.
File Name 3 |
Description |
Type |
Format |
---|---|---|---|
|
Mixture compositions in standard composition format for input to SCALE codes such as KENO |
out |
text |
|
Nuclide identifiers and weight fractions in format for MCNP material cards |
out |
text |
|
Total gamma source
intensity in MCNP
source format. Only
output if gamma
energy group
boundaries are
entered in input
array
|
out |
text |
|
Total neutron
source intensity in
MCNP source format.
Only output if
neutron energy
group boundaries
are entered in
input array
|
out |
text |
|
Gamma spectrum (photons/sec) by axial zone, enabled by “srcopt{ print=yes }”. |
out |
text |
|
Neutron spectrum (neutron/sec) by axial zone, enabled by “srcopt{ print=yes }”. |
out |
text |
|
Decay heat source (watts) by axial zone, enabled by “options{ decayheat=yes }” |
out |
text |
|
Output stacked ORIGEN ft71 files for each axial zone |
out |
binary |
|
Input stacked ORIGEN ft71 files for each axial zone |
in |
binary |
|
Output of stacked ORIGEN ft71 files for each pin and axial zone |
out |
binary |
|
Binary MeshView file of selected actinide masses by depletion cell |
out |
binary |
|
Plaintext MeshView file of selected actinide masses by depletion cell |
out |
text |
|
Binary MeshView file of selected fission product masses by depletion cell |
out |
binary |
|
Plaintext MeshView file of selected fission product masses by depletion cell |
out |
text |
|
Binary MeshView file of depletion node burnups |
out |
binary |
- 3
Note that all file names are prefixed by an identifier
${OUTBASENAME}
, where${OUTBASENAME}
is a prefix constructed from the input file base name followed by the character string given by input keywordprefix= *.*
For example, the input file named “my.inp” with prefix=sample would give an output prefixmy_sample
; e.g.,my_sample.f71
,my_sample.assm.f71
,my_sample_MCNP_matls.inp
, etc.
5.4.5.1. Generation of SCALE standard composition data file
If input parameter stdcomp=yes
is specified, ORIGAMI produces a text
file containing a SCALE standard composition description for each axial
interval. The file is written in the form of a stdcomp
block that can
be directly used as input to any SCALE module that requires a
composition block. If a 1D axial depletion model is used for the
assembly, the composition for each axial zone is given a unique mixture
number defined for an axial node “Z” as:
where NZ is the number of axial zones and asmid
is the input
identifier. For example, if there are 12 axial zones and the input for
asmid
is 20, then the mixture number associated with axial zone number
1 is mix = 1229, and the mixture for zone 12 is mix= 1240. If an
assembly is represented by a 3D multiple-pin model, the mixture number
is defined,
where X and Y correspond to the row and column numbers of the pin.
The nuclides components of the mixtures may be specified in the input
array nuccomp
, or by default the mixture may consist of the nuclides
given in Table 5.4.9, which are the nuclides
recommended in [ORIGAMIRGlW12] for burnup credit analysis, plus 16O.
The temperatures of the mixtures are set by the value of parameter
temper
, which defaults to a value of 293 Kelvin. The number densities
of the nuclides in the mixtures are calculated using the following expressions:
Where:
\(N_{Z}^{\left( i \right)}\) = number density of nuclide “i” in zone Z, in units of atoms of “i” per barn-cm of UO2;
\(\rho\) = density of UO2 (g/cc), defined by the input parameter
fdens
(default is 10.4 g/cc);\(M_{Z}^{(i)}\) = mass (g) of nuclide i in axial zone Z , obtained from ORIGEN calculation;
\(M_{Z} \cdot 10^{6}\) = mass (g) of uranium in axial zone Z, where MZ is given by Eq. (5.4.2);
A(i) = mass (g) of 1 mole of nuclide i;
0.8814 = weight fraction of uranium in UO2;
10-24 = cm3 per barn-cm.
The definitions of other parameters appearing in this equation are given in Sect. 5.4.3.4. An example of the standard composition file produced by ORIGAMI is given in Sect. 5.4.7, Example 5.4.12 (illustrated in sample problem 2, Example 5.4.11).
Nuclide |
ZAID |
Nuclide type |
---|---|---|
16O |
8016 |
light element |
234U |
92234 |
actinide |
235U |
92235 |
actinide |
236U |
92236 |
actinide |
238U |
92238 |
actinide |
237Np |
93237 |
actinide |
238Pu |
94238 |
actinide |
239Pu |
94239 |
actinide |
240Pu |
94240 |
actinide |
241Pu |
94241 |
actinide |
242Pu |
94242 |
actinide |
241Am |
95241 |
actinide |
243Am |
95243 |
actinide |
95Mo |
42095 |
fission product |
99Tc |
43099 |
fission product |
101Ru |
44101 |
fission product |
103Rh |
45103 |
fission product |
109Ag |
47109 |
fission product |
133Cs |
55133 |
fission product |
143Nd |
60143 |
fission product |
145Nd |
60145 |
fission product |
147Sm |
62147 |
fission product |
149Sm |
62149 |
fission product |
150Sm |
62150 |
fission product |
151Sm |
62151 |
fission product |
152Sm |
62152 |
fission product |
151Eu |
63151 |
fission product |
153Eu |
63153 |
fission product |
155Gd |
64155 |
fission product |
5.4.5.2. MCNP data files
If the input parameter mcnp=yes
is set in the options
block, the
computed weight fractions for the materials in each axial zone also are
output in a file in the format of MCNP material cards. These material
cards are designed to be coupled to a corresponding MCNP assembly
geometry using the same numbering convention for the depletion zones.
Sect. 5.4.7 shows an example of the MCNP material
information produced by ORIGAMI. The numbering convention of the MCNP
materials cards works by combining the axial and pin numbers into a material
card, where pins are counted sequentially by row, starting with the bottom-left
row of input, counting from left to right across each row to the top-right pin
(i.e., the bottom-left pin is pin #1, etc.). The pin numbers reset with
each axial zone, starting from the bottom zone, counting up from 1. The
naming convention for materials cards is thus the pin number (1-999)
followed by the zone number (1-99); for example, pin #15 of axial zone
#12 would be m1512. Accompanying each material card is a list of
ZAID numbers and final concentrations (following depletion/decay) for the
cell expressed in weight fractions. The weight fractions are given as negative
values in accordance with MCNP convention. The fuel density, which may be used
in the MCNP cell card, is equal to the value of the input parameter
fdens
.
When parameter mcnp=yes
is set, ORIGAMI also produces output files
containing the fuel assembly radiation source magnitude by depletion
zone, to support modeling with MCNP. The gamma/neutron source term cards
correspond to the total gamma or neutron intensity (particles/s) from
each respective depletion region, using the same numbering convention as
that for the MCNP material cards. The source magnitude is computed by
summing over the MG source spectra defined in Eq. (5.4.12).
(5.4.16)\[S_{Z}^{\left( p \right)} = \sum_{g}^{}{S_{Z,g}^{\left( p \right)}\ }\]
Where:
\(S_{Z}^{\left( p \right)}\) = total source magnitude (p/s) for particles of type p;
\(S_{Z,g}^{\left( p \right)}\) = multigroup source magnitude (p/s) for energy group g, and particles of type p
More details on the ORIGEN calculation of the source terms can be found in the ORIGEN section of SCALE documentation.
5.4.5.3. Decay heat calculation
When input parameter decayheat=yes
is specified in the input, a text
file containing the decay heat source by axial zone, summed over all
pins, is generated as output. The decay heat in zone Z is given in
watts and is computed from the
(5.4.17)\[H_{Z} = \sum_{i = 1}^{\text{itot}}{Q_{i}\lambda_{i}\frac{M_{Z}^{(i)}}{A^{(i)}} \cdot 1.602 \cdot 10^{-13} \cdot N_{A}} = 9.65 \cdot 10^{10} \sum_{i = 1}^{\text{itot}}{Q_{i}\lambda_{i}\frac{M_{Z}^{(i)}}{A^{(i)}}}\]
where:
Qi = decay energy in MeV for nuclide i;
\(\lambda_i\) = decay constant (s-1) for nuclide i;
\(M_{Z}^{(i)}\) = mass (g) of nuclide i in axial zone Z, obtained from ORIGEN calculation;
A(i) = mass (g) of 1 mole of nuclide i;
itot = total number of nuclides in burned fuel,
1.602×10-19 = number of joules per MeV.
An example output decay heat file produced by ORIGAMI is shown in Sect. 5.4.7, Example 5.4.13 (from sample problem 2).
5.4.5.4. ORIGEN results files
The ORIGEN computation for each depletion region produces an ORIGEN
binary concentrations output file, historically called an “ft71” because
it was written on “Fortran tape” number 71. The file named
$OUTBASENAME.f71
contains the concentrations for all depletion
regions, stacked within a single binary file, where ${OUTBASENAME}
is
the base of the output file name, e.g. the “my” in my.out
.
The order of stored cases on the f71 file corresponds to the order in which ORGAMI processes individual depletion cases, starting with the bottom-left row in the user-supplied power map (pin #1) and looping left to right, progressively up through the series of rows. This process repeats for each axial zone, starting from the bottom of the assembly and working upward (i.e., starting with pin #1, axial zone #1, looping through each pin on axial zone #1, and then proceeding to pin #1 on axial zone #2, etc.). This convention is the same as that used for TRITON arrays.
In addition, the compositions are blended over all pins for each axial
zone to obtain the axially-dependent compositions for the lumped
assembly, stored in a file named $OUTBASENAME.assm.f71
. If saved,
this file may be input as a restart file, as discussed in
Sect. 5.4.3.3.
5.4.5.5. Plotting features
ORIGAMI creates three separate mesh summaries of material inventories for individual depletion regions, useful for 3D visualization and inspection. These include maps of (1) depletion region burnups, (2) selected actinide concentrations (including isotopes of U, Pu, A m, and Cm), and (3) selected fission products typically used for burnup evaluation, including isotopes of Cs, Y, Ag, Rh, Ru, Eu, Sm, Nd, Gd, and others). Additionally, ORIGAMI outputs a separate mesh tally of individual node burnups. These outputs are described in Table 5.4.8.
Note
The mesh files are only created if the user specifies the (optional) input
arguments for assembly pitch (pitch
) and axial zone locations
(meshz
).
These output mesh-dependent maps can be visualized using the Java-based
Mesh File Viewer program included with SCALE. An example MeshView
visualization of one of these outputs is shown in Fig. 5.4.2
and Fig. 5.4.3. MeshView is installed in $SCALE/Meshview
,
where ${SCALE}
is the installation directory. A script to run MeshView is
located at $SCALE/cmds/meshview
.
5.4.6. Parallel Execution on Linux Clusters
For large 3D depletion problems it is advantageous to execute the ORIGEN calculations for different depletion regions in parallel. This can be done on Linux clusters using MPI. When parallel execution mode is enabled, ORIGAMI distributes the individual depletion cases across the pin rows, columns, and axial zones across several processors; the depletion calculation is thus split across several processors. ORIGAMI then collects the inventories from each calculation node and concatenates the output.
To execute ORIGAMI in parallel mode, a parallel-enabled MPI build of SCALE must be used and ORIGAMI should be invoked with the percent (%) prefix:
=%
<normal ORIGAMI input follows>
Additionally, for parallel jobs spanning multiple computational nodes (as opposed to those just using multiple processors on the same node, it is recommended to use the –T option to specify a common temporary directory (such as a network-mounted directory accessible to all nodes). This is due to the way ORIGAMI divides the problem space in parallel mode; each computational node stores its respective binary dump file of the individual pin/zone concentrations. Upon completion of execution, the master node must be able to locate these individual problem node-generated binary dump files; thus, by using a common temporary directory, ORIGAMI can correctly re-assembly the individual pinwise dumpfiles into a single consolidated “master” dump file.
The following is a typical execution command line to execute ORIGAMI in parallel.
scalerte –N [number of nodes] -M [machine file] –T [tmpdir] [input_file.inp]
For more information on executing SCALE in parallel, see the SCALE Readme file.
5.4.7. Sample Problems
This section shows sample problems for each of the three types of simulated assembly models: 0D fully lumped, 2D lumped axial depletion, and 3D pinwise depletion, and also demonstrates a restart case.
5.4.7.1. Sample problem 1: fully lumped assembly model
The first example, Example 5.4.10, corresponds to a fully-lumped assembly model in which the materials are depleted with a space-independent (i.e., assembly average) flux distribution. The assembly contains 0.38 MTU, and the fuel is 2.8 wt% enriched. The assembly also includes several non-fuel materials corresponding to cladding and other structural materials. Note that the non-fuel concentrations are specified in kg/MTU, and thus are not the actual total non-fuel masses in the 0.38 MTU assembly. The assembly is depleted for three cycles with specific powers of 40.0, 38.6, and 25.2 MW/MTU, respectively. The ORIGEN library data are interpolated for eight different burnup steps during the irradiation periods of the first two cycles, and for six burnup steps in the last cycle.
Table 5.4.10 gives the calculated actinide concentrations at the end of the third cycle.
=origami
title='fully lumped assembly model'
libs=[ ce14x14 ]
fuelcomp{
stdcomp(fuel){
base=uo2 iso[92234=0.02848 92235=3.2 92236=0.01472 92238=96.7568] }
mix(1){ comps[fuel=100] }
}
options{ mtu=0.38 ft71=all }
nonfuel=[ cr=3.366 mn=0.1525 fe=6.309 co=0.0302
ni=2.366 zr=516.3 sn=8.412 gd=2.860 ]
hist[
cycle{ power=40 burn=284 nlib=4 down=54 }
cycle{ power=38.6 burn=300 nlib=4 down=28 }
cycle{ power=25.2 burn=250 nlib=3 down=30 }
]
print{
nuc {
sublibs=[ac fp]
units=[grams moles]
total=no }
}
end
Nuclide * |
Mass (g) |
---|---|
234U |
6.820E+01 |
235U |
3.621E+03 |
236U |
1.487E+03 |
238U |
3.598E+05 |
237Np |
1.348E+02 |
238Pu |
3.862E+01 |
239Pu |
1.919E+03 |
240Pu |
7.820E+02 |
241Pu |
3.960E+02 |
242Pu |
1.394E+02 |
241Am |
1.474E+01 |
243Am |
2.491E+01 |
242Cm |
2.663E+00 |
244Cm |
5.698E+00 |
TOTAL |
6.820E+01 |
* Actinides with concentrations less than 0.0001 are not shown.
5.4.7.2. Sample problem 2: lumped axial depletion assembly model
The second example has the same lumped assembly and power history as sample problem 1, except in this case an axial power distribution is provided for eight zones, so that the fuel burnup will vary axially; the ORIGAMI input for this case is provided as Example 5.4.11. Also, the options to generate standard composition and decay output files are requested.
Table 5.4.11 gives the computed actinide concentrations in grams for the first four of the eight axial zones. Since the input axial power distribution is symmetrical about the assembly midplane, the last four zones have identical concentrations as the first four. The last column in the table shows actinide masses for the entire assembly.
Example 5.4.12 is a listing of the contents of the
compBlock file, which contains standard composition input for the eight
axial zones in the assembly at the end of cycle 3. A complete description of
the SCALE standard composition input format is given in the
XSPROC chapter The first entry on each line in
Example 5.4.12 corresponds to the SCALE nuclide identifier.
Only the default burnup credit analysis are included. The second entry is the
mixture number associated with a particular axial zone. The mixture number for
an axial zone is obtained using Eq. (5.4.14). The third entry is
always zero in this file, and the fourth entry corresponds to the number density
in atoms per barn-cm. The next entry on the line is the temperature, which has
the default value of 293.0 since the input parameter temper
was not
specified. The final entry is an “end” statement. The information in this file
can be used as the read comp
input block for any SCALE module.
Example 5.4.13 shows a listing of the file AxialDecayHeat, which contains the heat source at the end of the third cycle. The entries in the file correspond to the decay power in watts for the eight axial zones, which are computed using Eq. (5.4.17).
=origami
title= 'lumped axial-deplete assembly model'
libs=[ ce14x14 ]
fuelcomp{
uox(fuel2){ enrich=3.2 }
mix(1){ comps[fuel2=100] }
}
options{
mtu=0.38 stdcomp=yes decayheat=yes
}
pz=[ 1.0 2.0 3.0 4.0 4.0 3.0 2.0 1.0 ]
nonfuel=[ cr=3.366 mn=0.1525 fe=6.309 co=0.0302
ni=2.366 zr=516.3 sn=8.412 gd=2.860 ]
hist[
cycle{ power=40 burn=284 nlib=4 down=54 }
cycle{ power=38.6 burn=300 nlib=4 down=28 }
cycle{ power=25.2 burn=250 nlib=3 down=30 }
]
end
Nuclide |
Axial Zone 1 Mass (g) |
Axial Zone 2 Mass (g) |
Axial Zone 3 Mass (g) |
Axial Zone 4 Mass (g) |
TOTAL Mass (g) |
---|---|---|---|---|---|
234U |
1.1384E+01 |
9.4326E+00 |
7.6666E+00 |
6.11E+00 |
6.92E+01 |
235U |
9.7324E+02 |
5.9453E+02 |
3.3795E+02 |
1.78E+02 |
4.17E+03 |
236U |
1.0392E+02 |
1.6544E+02 |
2.0053E+02 |
2.15E+02 |
1.37E+03 |
238U |
4.5604E+04 |
4.5202E+04 |
4.4752E+04 |
4.43E+04 |
3.60E+05 |
237Np |
4.7874E+00 |
1.2622E+01 |
2.0984E+01 |
2.83E+01 |
1.33E+02 |
238Pu |
5.5445E-01 |
2.9024E+00 |
7.1722E+00 |
1.26E+01 |
4.65E+01 |
239Pu |
1.7378E+02 |
2.2968E+02 |
2.4438E+02 |
2.46E+02 |
1.79E+03 |
240Pu |
3.3124E+01 |
7.7894E+01 |
1.1457E+02 |
1.40E+02 |
7.30E+02 |
241Pu |
1.2974E+01 |
3.8401E+01 |
5.8714E+01 |
7.09E+01 |
3.62E+02 |
242Pu |
1.4543E+00 |
1.0115E+01 |
2.6393E+01 |
4.75E+01 |
1.71E+02 |
241Am |
5.3938E-01 |
1.5121E+00 |
2.0433E+00 |
2.12E+00 |
1.24E+01 |
243Am |
9.5029E-02 |
1.4341E+00 |
5.6093E+00 |
1.29E+01 |
4.00E+01 |
242Cm |
< 0.0001 |
2.0213E-01 |
4.7744E-01 |
7.56E-01 |
2.93E+00 |
244Cm |
< 0.0001 |
2.4685E-01 |
1.6315E+00 |
5.54E+00 |
1.49E+01 |
245Cm |
< 0.0001 |
< 0.0001 |
5.8836E-02 |
2.40E-01 |
6.11E-01 |
TOTAL |
4.6920E+04 |
4.6346E+04 |
4.5780E+04 |
4.5221E+04 |
3.6854E+05 |
o-16 1001 0 4.6395E-02 293.0 end
u-234 1001 0 5.6529E-06 293.0 end
u-235 1001 0 4.8120E-04 293.0 end
u-236 1001 0 5.1165E-05 293.0 end
u-238 1001 0 2.2263E-02 293.0 end
np-237 1001 0 2.3470E-06 293.0 end
pu-238 1001 0 2.7067E-07 293.0 end
pu-239 1001 0 8.4481E-05 293.0 end
pu-240 1001 0 1.6036E-05 293.0 end
pu-241 1001 0 6.2547E-06 293.0 end
pu-242 1001 0 6.9823E-07 293.0 end
am-241 1001 0 2.6003E-07 293.0 end
am-243 1001 0 4.5435E-08 293.0 end
mo-95 1001 0 1.5700E-05 293.0 end
tc-99 1001 0 1.7475E-05 293.0 end
ru-101 1001 0 1.5272E-05 293.0 end
rh-103 1001 0 9.4877E-06 293.0 end
ag-109 1001 0 7.6473E-07 293.0 end
cs-133 1001 0 1.8563E-05 293.0 end
nd-143 1001 0 1.4504E-05 293.0 end
nd-145 1001 0 1.0445E-05 293.0 end
sm-147 1001 0 1.5451E-06 293.0 end
sm-149 1001 0 8.0469E-08 293.0 end
sm-150 1001 0 3.3359E-06 293.0 end
sm-151 1001 0 3.5230E-07 293.0 end
sm-152 1001 0 1.7469E-06 293.0 end
eu-151 1001 0 1.5582E-09 293.0 end
eu-153 1001 0 9.1077E-07 293.0 end
gd-155 1001 0 1.3966E-09 293.0 end
o-16 1002 0 4.6394E-02 293.0 end
u-234 1002 0 4.6837E-06 293.0 end
u-235 1002 0 2.9395E-04 293.0 end
u-236 1002 0 8.1452E-05 293.0 end
u-238 1002 0 2.2067E-02 293.0 end
np-237 1002 0 6.1878E-06 293.0 end
pu-238 1002 0 1.4169E-06 293.0 end
pu-239 1002 0 1.1165E-04 293.0 end
pu-240 1002 0 3.7710E-05 293.0 end
pu-241 1002 0 1.8513E-05 293.0 end
pu-242 1002 0 4.8561E-06 293.0 end
am-241 1002 0 7.2896E-07 293.0 end
am-243 1002 0 6.8566E-07 293.0 end
mo-95 1002 0 2.9706E-05 293.0 end
tc-99 1002 0 3.3424E-05 293.0 end
ru-101 1002 0 3.0467E-05 293.0 end
rh-103 1002 0 1.8486E-05 293.0 end
ag-109 1002 0 2.2784E-06 293.0 end
cs-133 1002 0 3.5311E-05 293.0 end
nd-143 1002 0 2.4869E-05 293.0 end
nd-145 1002 0 1.9393E-05 293.0 end
sm-147 1002 0 2.4415E-06 293.0 end
sm-149 1002 0 1.0154E-07 293.0 end
sm-150 1002 0 7.3182E-06 293.0 end
sm-151 1002 0 4.4543E-07 293.0 end
sm-152 1002 0 3.4915E-06 293.0 end
eu-151 1002 0 1.1064E-09 293.0 end
eu-153 1002 0 2.5199E-06 293.0 end
gd-155 1002 0 2.5157E-09 293.0 end
o-16 1003 0 4.6392E-02 293.0 end
u-234 1003 0 3.8068E-06 293.0 end
u-235 1003 0 1.6709E-04 293.0 end
u-236 1003 0 9.8728E-05 293.0 end
u-238 1003 0 2.1847E-02 293.0 end
np-237 1003 0 1.0287E-05 293.0 end
pu-238 1003 0 3.5014E-06 293.0 end
pu-239 1003 0 1.1880E-04 293.0 end
pu-240 1003 0 5.5465E-05 293.0 end
pu-241 1003 0 2.8306E-05 293.0 end
pu-242 1003 0 1.2671E-05 293.0 end
am-241 1003 0 9.8507E-07 293.0 end
am-243 1003 0 2.6819E-06 293.0 end
mo-95 1003 0 4.2205E-05 293.0 end
tc-99 1003 0 4.7742E-05 293.0 end
ru-101 1003 0 4.5361E-05 293.0 end
rh-103 1003 0 2.6134E-05 293.0 end
ag-109 1003 0 4.1770E-06 293.0 end
cs-133 1003 0 5.0069E-05 293.0 end
nd-143 1003 0 3.1519E-05 293.0 end
nd-145 1003 0 2.6993E-05 293.0 end
sm-147 1003 0 2.8511E-06 293.0 end
sm-149 1003 0 1.2277E-07 293.0 end
sm-150 1003 0 1.1691E-05 293.0 end
sm-151 1003 0 5.2472E-07 293.0 end
sm-152 1003 0 5.0112E-06 293.0 end
eu-151 1003 0 9.0563E-10 293.0 end
eu-153 1003 0 4.4446E-06 293.0 end
gd-155 1003 0 4.0054E-09 293.0 end
o-16 1004 0 4.6390E-02 293.0 end
u-234 1004 0 3.0343E-06 293.0 end
u-235 1004 0 8.7951E-05 293.0 end
u-236 1004 0 1.0588E-04 293.0 end
u-238 1004 0 2.1605E-02 293.0 end
np-237 1004 0 1.3864E-05 293.0 end
pu-238 1004 0 6.1605E-06 293.0 end
pu-239 1004 0 1.1946E-04 293.0 end
pu-240 1004 0 6.7542E-05 293.0 end
pu-241 1004 0 3.4172E-05 293.0 end
pu-242 1004 0 2.2786E-05 293.0 end
am-241 1004 0 1.0210E-06 293.0 end
am-243 1004 0 6.1463E-06 293.0 end
mo-95 1004 0 5.3319E-05 293.0 end
tc-99 1004 0 6.0395E-05 293.0 end
ru-101 1004 0 5.9831E-05 293.0 end
rh-103 1004 0 3.2151E-05 293.0 end
ag-109 1004 0 6.2338E-06 293.0 end
cs-133 1004 0 6.2779E-05 293.0 end
nd-143 1004 0 3.4995E-05 293.0 end
nd-145 1004 0 3.3350E-05 293.0 end
sm-147 1004 0 2.9202E-06 293.0 end
sm-149 1004 0 1.4469E-07 293.0 end
sm-150 1004 0 1.6101E-05 293.0 end
sm-151 1004 0 6.0099E-07 293.0 end
sm-152 1004 0 6.3684E-06 293.0 end
eu-151 1004 0 8.1899E-10 293.0 end
eu-153 1004 0 6.4006E-06 293.0 end
gd-155 1004 0 5.5315E-09 293.0 end
o-16 1005 0 4.6390E-02 293.0 end
u-234 1005 0 3.0343E-06 293.0 end
u-235 1005 0 8.7951E-05 293.0 end
u-236 1005 0 1.0588E-04 293.0 end
u-238 1005 0 2.1605E-02 293.0 end
np-237 1005 0 1.3864E-05 293.0 end
pu-238 1005 0 6.1605E-06 293.0 end
pu-239 1005 0 1.1946E-04 293.0 end
pu-240 1005 0 6.7542E-05 293.0 end
pu-241 1005 0 3.4172E-05 293.0 end
pu-242 1005 0 2.2786E-05 293.0 end
am-241 1005 0 1.0210E-06 293.0 end
am-243 1005 0 6.1463E-06 293.0 end
mo-95 1005 0 5.3319E-05 293.0 end
tc-99 1005 0 6.0395E-05 293.0 end
ru-101 1005 0 5.9831E-05 293.0 end
rh-103 1005 0 3.2151E-05 293.0 end
ag-109 1005 0 6.2338E-06 293.0 end
cs-133 1005 0 6.2779E-05 293.0 end
nd-143 1005 0 3.4995E-05 293.0 end
nd-145 1005 0 3.3350E-05 293.0 end
sm-147 1005 0 2.9202E-06 293.0 end
sm-149 1005 0 1.4469E-07 293.0 end
sm-150 1005 0 1.6101E-05 293.0 end
sm-151 1005 0 6.0099E-07 293.0 end
sm-152 1005 0 6.3684E-06 293.0 end
eu-151 1005 0 8.1899E-10 293.0 end
eu-153 1005 0 6.4006E-06 293.0 end
gd-155 1005 0 5.5315E-09 293.0 end
o-16 1006 0 4.6392E-02 293.0 end
u-234 1006 0 3.8068E-06 293.0 end
u-235 1006 0 1.6709E-04 293.0 end
u-236 1006 0 9.8728E-05 293.0 end
u-238 1006 0 2.1847E-02 293.0 end
np-237 1006 0 1.0287E-05 293.0 end
pu-238 1006 0 3.5014E-06 293.0 end
pu-239 1006 0 1.1880E-04 293.0 end
pu-240 1006 0 5.5465E-05 293.0 end
pu-241 1006 0 2.8306E-05 293.0 end
pu-242 1006 0 1.2671E-05 293.0 end
am-241 1006 0 9.8507E-07 293.0 end
am-243 1006 0 2.6819E-06 293.0 end
mo-95 1006 0 4.2205E-05 293.0 end
tc-99 1006 0 4.7742E-05 293.0 end
ru-101 1006 0 4.5361E-05 293.0 end
rh-103 1006 0 2.6134E-05 293.0 end
ag-109 1006 0 4.1770E-06 293.0 end
cs-133 1006 0 5.0069E-05 293.0 end
nd-143 1006 0 3.1519E-05 293.0 end
nd-145 1006 0 2.6993E-05 293.0 end
sm-147 1006 0 2.8511E-06 293.0 end
sm-149 1006 0 1.2277E-07 293.0 end
sm-150 1006 0 1.1691E-05 293.0 end
sm-151 1006 0 5.2472E-07 293.0 end
sm-152 1006 0 5.0112E-06 293.0 end
eu-151 1006 0 9.0563E-10 293.0 end
eu-153 1006 0 4.4446E-06 293.0 end
gd-155 1006 0 4.0054E-09 293.0 end
o-16 1007 0 4.6394E-02 293.0 end
u-234 1007 0 4.6837E-06 293.0 end
u-235 1007 0 2.9395E-04 293.0 end
u-236 1007 0 8.1452E-05 293.0 end
u-238 1007 0 2.2067E-02 293.0 end
np-237 1007 0 6.1878E-06 293.0 end
pu-238 1007 0 1.4169E-06 293.0 end
pu-239 1007 0 1.1165E-04 293.0 end
pu-240 1007 0 3.7710E-05 293.0 end
pu-241 1007 0 1.8513E-05 293.0 end
pu-242 1007 0 4.8561E-06 293.0 end
am-241 1007 0 7.2896E-07 293.0 end
am-243 1007 0 6.8566E-07 293.0 end
mo-95 1007 0 2.9706E-05 293.0 end
tc-99 1007 0 3.3424E-05 293.0 end
ru-101 1007 0 3.0467E-05 293.0 end
rh-103 1007 0 1.8486E-05 293.0 end
ag-109 1007 0 2.2784E-06 293.0 end
cs-133 1007 0 3.5311E-05 293.0 end
nd-143 1007 0 2.4869E-05 293.0 end
nd-145 1007 0 1.9393E-05 293.0 end
sm-147 1007 0 2.4415E-06 293.0 end
sm-149 1007 0 1.0154E-07 293.0 end
sm-150 1007 0 7.3182E-06 293.0 end
sm-151 1007 0 4.4543E-07 293.0 end
sm-152 1007 0 3.4915E-06 293.0 end
eu-151 1007 0 1.1064E-09 293.0 end
eu-153 1007 0 2.5199E-06 293.0 end
gd-155 1007 0 2.5157E-09 293.0 end
o-16 1008 0 4.6395E-02 293.0 end
u-234 1008 0 5.6529E-06 293.0 end
u-235 1008 0 4.8120E-04 293.0 end
u-236 1008 0 5.1165E-05 293.0 end
u-238 1008 0 2.2263E-02 293.0 end
np-237 1008 0 2.3470E-06 293.0 end
pu-238 1008 0 2.7067E-07 293.0 end
pu-239 1008 0 8.4481E-05 293.0 end
pu-240 1008 0 1.6036E-05 293.0 end
pu-241 1008 0 6.2547E-06 293.0 end
pu-242 1008 0 6.9823E-07 293.0 end
am-241 1008 0 2.6003E-07 293.0 end
am-243 1008 0 4.5435E-08 293.0 end
mo-95 1008 0 1.5700E-05 293.0 end
tc-99 1008 0 1.7475E-05 293.0 end
ru-101 1008 0 1.5272E-05 293.0 end
rh-103 1008 0 9.4877E-06 293.0 end
ag-109 1008 0 7.6473E-07 293.0 end
cs-133 1008 0 1.8563E-05 293.0 end
nd-143 1008 0 1.4504E-05 293.0 end
nd-145 1008 0 1.0445E-05 293.0 end
sm-147 1008 0 1.5451E-06 293.0 end
sm-149 1008 0 8.0469E-08 293.0 end
sm-150 1008 0 3.3359E-06 293.0 end
sm-151 1008 0 3.5230E-07 293.0 end
sm-152 1008 0 1.7469E-06 293.0 end
eu-151 1008 0 1.5582E-09 293.0 end
eu-153 1008 0 9.1077E-07 293.0 end
gd-155 1008 0 1.3966E-09 293.0 end
7.11397E+02
1.43786E+03
2.18631E+03
2.95428E+03
2.95428E+03
2.18631E+03
1.43786E+03
7.11397E+02
5.4.7.3. Sample problem 3: restart decay calculation for lumped axial depletion assembly model
The third example shows a restart decay-only calculation, using the
ORIGEN ft71 binary file obtained from sample problem 2. This case
calculates the composition of the burned fuel produced in sample problem
2 after 100,000 additional days of decay. The input this problem is
given in Example 5.4.15. Because the input parameter
restart=yes is specified, the initial composition of the assembly is
obtained from a file named assembly_restart.f71
. The shell input that
precedes the ORIGAMI input in Example 5.4.15 copies the output ft71
file produced in sample problem 2, which was named assembly_dump.f71
,
into a file named assembly_restart.f71
in the temporary directory for
SCALE calculations. The restart file contains the complete inventory of
nuclide compositions for eight axial zones. Because this restart case is
decay only (i.e., power
value is not given in the power-history
block), it is necessary to provide the input parameter nz=8 because
this value is used to determine how many axial zones were used in the previous
burnup calculations.
Table 5.4.12 shows the actinide composition of the first four axial of the (symmetrical) eight zones after 100,000 days of decay. The initial masses of these nuclides before decay are the values given in numref:ex-origami-prob2-stdcmp. The last column in Table 5.4.12 shows actinide masses for the entire assembly after the decay period.
=origami
title= 'lumped axial-deplete assembly model'
libs=[ ce14x14 ]
fuelcomp{
%3.2 w/o
uox(fuel){ enrich=3.2 }
mix(1){ comps[fuel=100] }
}
options[ mtu=0.38 relnorm=no ]
pz=[ 1.0 2.0 3.0 4.0 4.0 3.0 2.0 1.0 ]
nonfuel=[ cr=3.366 mn=0.1525 fe=6.309 co=0.0302
ni=2.366 zr=516.3 sn=8.412 gd=2.860 ]
hist[
cycle{ power=40 burn=284 nlib=8 down=54 }
cycle{ power=38.6 burn=300 nlib=8 down=28 }
cycle{ power=25.2 burn=250 nlib=6 down=30 }
]
end
=shell
mv \*.assm.f71 assembly_restart.f71
end
=origami
title= 'restart decay'
asmid= 22
libs=[ ce14x14 ]
prefix=origam3
options{
stdcomp=yes decayheat=yes relnorm=no restart=yes nz=8
}
pz=[ 1.0 2.0 3.0 4.0 4.0 3.0 2.0 1.0 ]
hist[
cycle{ down=100000 }
]
end
=shell
rm assembly_restart.f71
rm ${OUTDIR}/\*origam3\*
end
Nuclide |
Axial Zone 1 Mass (g) |
Axial Zone 2 Mass (g) |
Axial Zone 3 Mass (g) |
Axial Zone 4 Mass (g) |
TOTAL Mass (g) |
---|---|---|---|---|---|
234U |
1.1889E+01 |
1.2133E+01 |
1.4319E+01 |
1.7738E+01 |
1.1216E+02 |
235U |
9.7454E+02 |
5.9616E+02 |
3.3963E+02 |
1.7955E+02 |
4.1798E+03 |
236U |
1.0486E+02 |
1.6764E+02 |
2.0378E+02 |
2.1907E+02 |
1.3907E+03 |
238U |
4.5604E+04 |
4.5202E+04 |
4.4752E+04 |
4.4256E+04 |
3.5963E+05 |
237Np |
9.2242E+00 |
2.5723E+01 |
4.0929E+01 |
5.2246E+01 |
2.5625E+02 |
238Pu |
6.8535E-02 |
3.6104E-01 |
8.8478E-01 |
1.5422E+00 |
5.7132E+00 |
239Pu |
1.7243E+02 |
2.2794E+02 |
2.4262E+02 |
2.4413E+02 |
1.7742E+03 |
240Pu |
3.2192E+01 |
7.5957E+01 |
1.1297E+02 |
1.4095E+02 |
7.2412E+02 |
241Pu |
< 0.0001 |
< 0.0001 |
< 0.0001 |
< 0.0001 |
< 0.0001 |
242Pu |
1.4538E+00 |
1.0107E+01 |
2.6379E+01 |
4.7456E+01 |
1.7079E+02 |
241Am |
8.9945E+00 |
2.6564E+01 |
4.0451E+01 |
4.8623E+01 |
2.4927E+02 |
243Am |
9.2577E-02 |
1.3965E+00 |
5.4616E+00 |
1.2516E+01 |
3.8934E+01 |
242Cm |
< 0.0001 |
< 0.0001 |
< 0.0001 |
< 0.0001 |
< 0.0001 |
244Cm |
< 0.0001 |
< 0.0001 |
< 0.0001 |
< 0.0001 |
< 0.0001 |
245Cm |
< 0.0001 |
< 0.0001 |
5.7288E-02 |
2.3382E-01 |
5.9479E-01 |
TOTAL |
4.6920E+04 |
4.6346E+04 |
4.5780E+04 |
4.5220E+04 |
3.6853E+05 |
5.4.7.4. Sample problem 4: Simplified 3D multi-pin model
The fourth example is a simulation of a simplified 3D depletion model.
The ORIGAMI 3D model normally includes all fuel pins within the
assembly, such as a 14×14 array. However to keep this example case
simple and the execution time low, only a 2×2 array of four individual
pins is considered for illustrative purposes. An axial fractional power
distribution is also specified for two axial zones. Therefore the total
number of depletion regions will be eight – two axial for each of the
four pins. Two different ORIGEN libraries are used to obtain cross
sections for the four pins. This is done whenever fuel pins in different
locations in the assembly have significantly different neutron spectra,
such as if some pins are adjacent to a control rod. In this sample
problem, ORIGEN libraries for two different types of assembly designs CE
(Combustion Engineering) 14×14 and 16×16 assembly designs, respectively
are used to demonstrate the use of pin-dependent libraries, although in
reality the ORIGEN libraries normally would be pre-generated for
different pin locations within a single type of assembly configuration.
The values specified in libmap
indicate which library is to be used
for each pin location. Example 5.4.15 shows the input for this
sample problem.
=origami
title= 'multi-pin; multi-library pin-deplete model'
prefix= origam4
libs=[ ce14x14 ce16x16 ]
fuelcomp{
%3.2 w/o
stdcomp(fuel){ base=uo2 iso[92234=0.028569 92235=3.21 92236=0.014766
92238=96.746665] }
mix(1){ comps[fuel=100] }
}
options{ mtu=0.4 decayheat=yes }
libmap=[ 1 1
2 2 ]
pxy=[ 0.284 0.283
0.218 0.215 ]
pz=[ 0.55 0.45 ]
hist[
cycle{ power=39.78 burn=284.0 nlib=2 down=54.0 }
]
end
Table 5.4.13 shows selected actinide compositions for the first row of two pins, that is, locations (1,1) and (1,2), for each of the two axial zones. The blended compositions over all fuel pins, for the two axial zones, are given in Table 5.4.14. The output decay heat file for the assembly is shown in Table 5.4.15, as a function of axial zone, summed over all pins. Note that this file has the prefix “sample4_” appended to the standard file name, since prefix=sample4 is specified in the input.
Nuclide |
pin (1,1) Axial Zone 1 Mass (g) |
pin (1,1) Axial Zone 2 Mass (g) |
pin (1,2) Axial Zone 1 Mass (g) |
pin (1,2) Axial Zone 2 Mass (g) |
---|---|---|---|---|
234U |
1.2115E+01 |
1.2493E+01 |
1.2143E+01 |
1.2516E+01 |
235U |
1.0701E+03 |
1.1528E+03 |
1.0762E+03 |
1.1581E+03 |
236U |
1.0383E+02 |
8.9286E+01 |
1.0277E+02 |
8.8348E+01 |
237U |
1.0664E-03 |
< 0.0001 |
1.0428E-03 |
< 0.0001 |
238U |
4.8003E+04 |
4.8074E+04 |
4.8009E+04 |
4.8078E+04 |
237Np |
4.8000E+00 |
3.6009E+00 |
4.7055E+00 |
3.5303E+00 |
239Np |
5.8742E-07 |
4.4485E-07 |
5.7555E-07 |
4.3692E-07 |
238Pu |
4.7198E-01 |
2.9453E-01 |
4.5684E-01 |
2.8512E-01 |
239Pu |
1.8855E+02 |
1.6706E+02 |
1.8705E+02 |
1.6560E+02 |
240Pu |
3.3235E+01 |
2.5225E+01 |
3.2625E+01 |
2.4736E+01 |
241Pu |
1.3906E+01 |
9.2953E+00 |
1.3537E+01 |
9.0304E+00 |
242Pu |
1.3733E+00 |
7.3260E-01 |
1.3161E+00 |
7.0081E-01 |
241Am |
2.3603E-01 |
1.5773E-01 |
2.2978E-01 |
1.5322E-01 |
243Am |
8.4143E-02 |
< 0.0001 |
7.9365E-02 |
< 0.0001 |
TOTAL |
4.9432E+04 |
4.9535E+04 |
4.9440E+04 |
4.9541E+04 |
- 4
Values < 0.0001 are not shown
Nuclide |
Axial Zone 1 Mass (g) |
Axial Zone 2 Mass (g) |
TOTAL Mass (g) |
---|---|---|---|
234U |
4.7388E+01 |
4.9082E+01 |
9.6469E+01 |
235U |
4.0115E+03 |
4.3778E+03 |
8.3894E+03 |
236U |
4.5851E+02 |
3.9537E+02 |
8.5387E+02 |
238U |
1.9184E+05 |
1.9216E+05 |
3.8399E+05 |
237Np |
2.2821E+01 |
1.7132E+01 |
3.9953E+01 |
238Pu |
2.5739E+00 |
1.6049E+00 |
4.1789E+00 |
239Pu |
7.8246E+02 |
6.9963E+02 |
1.4821E+03 |
240Pu |
1.5436E+02 |
1.1801E+02 |
2.7238E+02 |
241Pu |
6.7918E+01 |
4.6455E+01 |
1.1437E+02 |
242Pu |
8.1693E+00 |
4.4411E+00 |
1.2610E+01 |
241Am |
1.1476E+00 |
7.8696E-01 |
1.9346E+00 |
243Am |
6.0150E-01 |
2.5995E-01 |
8.6145E-01 |
TOTAL |
1.9740E+05 |
1.9787E+05 |
3.9526E+05 |
6.96472E+03 5.72539E+03 |
5.4.7.5. Sample problem 5: PWR 3D assembly model
This sample problem shows the input for a simulated full 3D pressurized
water reactor (PWR) assembly-depletion model, which corresponds to a
16×16 lattice with 26 axial zones. Example 5.4.16 shows the
ORIGAMI input for this case. The arrays pxy
and pz
define the 3D XY-Z
fractional power distribution. Four different pre-processed ORIGEN libraries
are used to describe the pin-averaged ORIGEN cross-sections for the assembly.
The array libmap
assigns these libraries to the appropriate pin locations.
It can be seen that the libmap
array contains values of zero at 21 locations.
These correspond to non-depleting (i.e., zero power) locations. The input
includes the information (parameter pitch
, and array z= ) necessary to
generate 3D mesh summary maps for subsequent visualization. In this case, the
axial mesh is not uniform. Since a total of 6110 ORIGEN cases are executed for
the depletable pins, this ORIGAMI calculation was performed in parallel using
MPI. Figure 5.4.3 shows a plot of the axial burnup distribution, summed over
all pins.
=%origami
title= 'PWR 3D deplete model'
prefix= pwr
options{ pitch= 19.816 }
fuelcomp{
uox(fuel){ enrich=3.5 }
mix(1){ comps[fuel=100] }
}
libs=[ lib1 lib2 lib3 lib4]
libmap=[
3 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3
2 1 1 1 1 4 1 1 1 1 4 1 1 1 1 2
2 1 1 4 4 0 4 4 1 4 0 4 4 1 1 2
2 1 4 0 4 4 4 0 4 1 4 4 0 4 1 2
2 1 4 4 1 4 1 4 1 1 4 1 4 4 1 2
2 4 0 4 4 0 4 1 1 4 0 4 4 0 4 2
2 1 4 4 1 4 1 1 1 1 4 1 1 4 1 2
2 1 4 0 4 1 1 4 1 1 1 1 4 1 1 2
2 1 1 4 1 1 4 0 4 1 1 4 0 4 1 2
2 1 4 1 1 4 1 4 1 1 4 1 4 4 1 2
2 4 0 4 4 0 4 1 1 4 0 4 4 0 4 2
2 1 4 4 1 4 1 4 1 1 4 1 4 4 1 2
2 1 4 0 4 4 4 0 4 1 4 4 0 4 1 2
2 1 1 4 4 0 4 4 1 4 0 4 4 1 1 2
2 1 1 1 1 4 1 1 1 1 4 1 1 1 1 2
3 2 2 2 2 2 2 2 2 2 2 2 2 2 2 3 ]
pxy=[
0.99 0.98 0.98 0.99 0.99 0.99 0.99 0.99
0.99 0.99 0.99 0.99 0.98 0.98 0.97 0.98
0.99 0.99 0.99 1.00 1.01 1.02 1.00 1.00
1.00 1.01 1.02 1.00 0.99 0.98 0.98 0.98
1.00 1.00 1.01 1.03 1.03 0.00 1.03 1.01
1.03 1.04 0.00 1.03 1.02 1.00 0.99 0.98
1.01 1.01 1.03 0.00 1.04 1.04 1.02 0.00
1.03 1.04 1.04 1.04 0.00 1.02 1.00 0.99
1.01 1.02 1.02 1.05 0.73 1.04 1.02 1.02
1.03 1.03 1.04 0.72 1.04 1.04 1.01 1.00
1.02 1.04 0.00 1.05 1.04 0.00 1.03 1.01
1.01 1.03 0.00 1.03 1.04 0.00 1.02 1.00
1.02 1.03 1.02 1.05 1.04 1.04 1.02 1.01
1.01 1.02 1.03 1.02 1.02 1.03 1.01 1.00
1.01 1.02 1.04 0.00 1.04 1.02 1.02 1.03
1.01 1.01 1.01 1.02 1.03 1.02 1.00 1.00
1.00 1.01 1.02 1.03 1.02 1.02 1.03 0.00
1.02 1.01 1.01 1.03 0.00 1.02 0.99 0.98
1.00 1.01 1.03 1.02 1.02 1.03 1.03 1.03
1.01 1.01 1.03 1.02 1.03 1.03 1.00 0.99
1.01 1.02 0.00 1.04 1.03 0.00 1.03 1.01
1.01 1.02 0.00 1.03 1.03 0.00 1.01 0.98
1.00 1.01 1.04 1.04 0.72 1.04 1.03 1.03
1.01 1.01 1.02 0.71 1.03 1.02 0.99 0.98
1.00 1.00 1.02 0.00 1.04 1.04 1.04 0.00
1.02 1.01 1.03 1.03 0.00 1.01 0.98 0.97
0.99 0.99 1.01 1.03 1.04 0.00 1.04 1.03
1.01 1.02 0.00 1.02 1.01 0.99 0.97 0.97
0.99 0.99 0.99 1.00 1.01 1.03 1.01 1.00
1.00 1.00 1.01 1.00 0.99 0.97 0.97 0.97
1.00 0.99 1.00 1.00 1.01 1.01 1.01 1.00
0.99 0.99 0.99 0.99 0.98 0.97 0.97 0.97 ]
pz=[0.486645842
0.510544887
0.641121243
0.798557507
0.931372279
1.063949280
1.173174524
1.178015382
1.241701554
1.247451593
1.203231683
1.228462686
1.237668911
1.221002529
1.191997899
1.231513011
1.222065701
1.172711869
1.200902470
1.164812132
1.083204453
0.931028309
0.810656652
0.700324838
0.611466339
0.516416427 ]
meshz=[ 0.0 2.0 6.0 10.0 16.5 23.0 37.0 57.0 77.0 97.0 16.0
136.0 156.0 176.0 196.0 216.0 236.0 256.0 276.0 296.0
316.0 328.5 344.0 352.0 355.5 359.0 366.0 ]
hist[
cycle{ power=49.395 burn=385 nlib=3 down=52 }
cycle{ power=43.772 burn=360 nlib=2 down=7673 }
]
end
References
- ORIGAMIOWHR94
O. W. Hermann, C. V. Parks and J. P. Renier. Technical Support for a Proposed Decay Heat Guide Using SAS2H/ORIGEN Data. Technical Report NUREG/CR-5625 (ORNL-6698), Martin Marietta Energy Systems, Inc., Oak Ridge National Laboratory, 9 1994.
- ORIGAMIRGI10
G. Radulescu, I. C. Gauld, and G. Ilas. SCALE 5.1 Predictions of PWR Spent Nuclear Fuel Isotopic Compositions. Technical Report ORNL/TM-2010/44, Oak Ridge National Laboratory, Oak Ridge, TN (USA), 3 2010.
- ORIGAMIRGlW12(1,2)
G. Radulescu, I. C. Gauld, G. llas, and J. C. Wagner. An Approach for Validating Actinide and Fission Product Burnup Credit Criticality Safety Analyses-Isotopic Composition Predictions. Technical Report NUREG/CR-7108, ORNL/TM-2011/509, Oak Ridge National Laboratory, Oak Ridge, TN (USA), 4 2012.
- ORIGAMISGRT12
S. Skutnik, I.C. Gauld, C.E. Romano, and H.R. Trellue. Creating NDA 'Working Standards' through High-Fidelity Spent Fuel Modeling. In Proceedings of the Institute of Nuclear Materials Management, 53rd Annual Meeting. Orlando, FL, 7 2012.
- ORIGAMISHDLG13(1,2)
S. Skutnik, F. Havlůj, D. Lago, and I. Gauld. Development of an Object-Oriented ORIGEN for Advanced Nuclear Fuel Modeling Applications. In International Conference on Mathematics and Computational Methods Applied to Nuclear Science & Engineering (M&C 2013). Sun Valley, ID, 5 2013.